IVWF Variable Flow

Kitz SCT IVWF Variable Flow series product.

IVWF Variable Flow

The IVWF series shutoff valves have a simple structure, and can be installed in the vacuum exhaust line. The valve shuts off flow when the flapper type mechanism is rotated 90°.

Product Details

Specifications
Size25A50A80A100A
Orifice Inch(mm)φ1.30 (33.0)φ2.02 (51.3)φ3.07 (78.0)φ3.94 (100.0)
Pressure Range1.4x10-10 psia (1x10-6 ~2x105 Pa (abs) [0.1MPa(G)])
Maximum Pressure Differential at the Seat14.6 psig (0.101 MPa(G)) (Positive / Back Pressure)
Fluid Temperature-15~100ºC
Leak RatesAcross the Seat He Leak Rates≤ 1×10-9 sccs (≤ 1×10-10 Pa·m3/sec)
Inboard He Leak Rates≤ 1×10-9 sccs (≤ 1×10-10 Pa·m3/sec)
Cycle LifeTested for 1 million cycles in atmospheric pressure
ConnectionCompatible with ISO KF flange, JIS VF/VG flange, and other standard connections
PRODUCT CODE KEY
Model
Size
Operation
Valve Material
Connection (Seat Side)
Connection
Seat Material
Custom Specifications
Proximity Switch
Proximity Switch Categories
Open/Close Display Plate※
IVWF
50
F
S
-
VF
G
F
-
Specific Code
-
W
-
NR
-
OC
IVWF - I-shape Vacuum Butterfly Valve
25: 25A
50: 50A
80: 80A
100: 100A
F: Flow Control
S: Straight
NW: ISO KF Flange
VF: JIS VF Flange
VG: JIS VG Fange
CF: ConFlat Flange
Not Shown: Same Cases As (Seat Side) Omitted
F: JIS VF Flange
G: JIS VG Flange
F: Fluorine Rubber
Not Shown: Standard Products Are Omitted
Not Displayed: No Switch
SO: With Switch on Fully Open Side
SC: With Switch on Fully Closed Side
W: With Fully Open/fully Closed Switches
NR: PD31L3 Switch with Contacts (2 wires)
NS: PE34L3 Switch with Contacts (2 wires)
OC: With Open/Close Display Plate
Not Shown: Without Open/Close Display Plate

*We handle materials and shapes other than those noted.
*We also handle these valves with heaters attached as special order items. For details please ask to the sales representative.
※Pneumatic only