Specifications | |
Temperature control range | Room temperature-max 180°C |
Temperature sensor | K-type thermocouple |
Heater rating | AC 100V internal heater 400W / external heater 400W |
AC 200V internal heater 800W / external heater 800W | |
Power source | AC 100V/200V |
Warning signal output | Heater malfunction reports 1a output for each heater (Reports heater disconnection and overheating) |
Warning display | A buzzer sounds and a lamp lights up when there is a heater disconnection or overheating malfunction.(Independent warnings for internal and external heaters; The buzzer can be turned off) |
Safety mechanism | Internal and external heaters can be individually interrupted when there is a heater malfunction Power interrupt function upon current surge or short |
Operating environment | 0-50°C, 45-85%RH |
Open/close display | Valve position detected by magnetic proximity switch |